Calibration Gas
Calibration gas for gas detectors, from single gases to 4 gas mixes. Start with a mix type. Then choose your gas, concentration and cylinder size.
Non-Reactive Single Mix
Individual gases in a balance gas.
CO · CO₂ · CH₄ · O₂Reactive Single Mix
Precision mixtures for reactive gases.
H₂S · NH₃ · SO₂ · Cl₂Non-Reactive Multi Mix
Multiple components. One cylinder.
CO / CH₄ / O₂Reactive Multi Mix
Combined mixtures for multi-gas detectors.
H₂S / CO / CH₄ / O₂Regulators
Find the right flow for your cylinder.
FIXED · DEMAND · DIALAccessories
Complete your calibration setup.
CALIBRATION ESSENTIALSTypes of Calibration Gas
Non-Reactive Single Mix
One gas, such as methane, carbon monoxide, carbon dioxide, oxygen or propane, blended in a balance of air or nitrogen. These gases are stable, so they are filled in aluminum or steel cylinders. Use them to bump test and calibrate single-gas detectors, or one sensor at a time on a multi-gas instrument. Pick the gas, then choose the concentration and cylinder size on the product page.
Reactive Single Mix
One reactive gas, such as hydrogen sulfide, ammonia, chlorine, sulfur dioxide or hydrogen cyanide, blended in a balance of air or nitrogen. Reactive gases are filled in aluminum cylinders suited to reactive gas. Use them to bump test and calibrate toxic gas detectors and sensors. Pick the gas, then choose the concentration and cylinder size on the product page.
Non-Reactive Multi Mix
Two to four non-reactive gases, such as carbon monoxide, carbon dioxide, methane and oxygen, in one cylinder. One cylinder checks several sensors at once, so there are fewer cylinders to carry and buy. These mixes suit multi-gas detectors, landfill gas monitors and indoor air quality instruments. Choose the mix and cylinder size on the product page.
Reactive Multi Mix
Hydrogen sulfide, carbon monoxide, an LEL gas (methane or pentane) and oxygen in one cylinder, known as 4 gas calibration gas, plus a 5 gas mix that adds sulfur dioxide. It is the standard bump test and calibration gas for 4 gas confined space monitors, filled in aluminum cylinders suited to reactive gas. The most common mix is 25 ppm H2S, 100 ppm CO, 50% LEL methane and 18% oxygen.
Regulators
A regulator sets how calibration gas flows from the cylinder to the detector. Fixed flow regulators deliver a steady set rate, demand flow regulators release gas only when a pumped instrument draws it, and dial-a-flow regulators let you adjust the rate. Choose by the cylinder and by the gas: nickel-plated brass for non-reactive gases, stainless steel for reactive gases.
Accessories
Carrying cases keep cylinders and regulators protected and together in the field. Cases are sized for McNeill cylinders, from two 17 L cylinders to three 105 L cylinders, with room for regulators.
Popular Calibration Gas

4-Gas: Hydrogen Sulfide / Carbon Monoxide / Methane / Oxygen / Nitrogen Calibration Gas

Hydrogen Sulfide Calibration Gas

Methane Calibration Gas

Carbon Monoxide Calibration Gas
Bump Test or Full Calibration?
A gas detector bump test is a quick dose of known gas to prove the sensors and alarms respond. A calibration adjusts the reading to match a known concentration. Both need certified calibration gas and a regulator matched to the cylinder; add a carrying case for a complete gas detector calibration kit. More in our gas detector calibration guide.
A Different Gas, Concentration or Cylinder?
Talk to McNeill about a custom mixture for your application.